# results_fuse_general_a_grid

Grid **`fuse_general` mix weight a** on published SW2 decoder↔clf evidence streams (4 dec + 4 clf10-sw2): `d=(1-a)z_dec + a·z_clf`, a∈{0.0, 0.25, 0.5, 0.75, 1.0}. Optional: each a then fixed Acc-tip `hard_abs_swmix|t1|s1` (from sw2_swmix_blend). **Not** soft-w SW2↔swmix/hp30 re-grid, ≠ tip Platt/domain-emis, ≠ IRM↔synth post-process.

HMM preset **0.994 / 0.8**. Code: `fuse_general_a_grid.py`. JSON: `results/research/fuse_general_a_grid.json`.

## Selection (mean LODO Acc then H; never AASD/Carta)

**SELECTED `a=0.75`** — mean LODO H **0.7972** Acc **72.80**

| Held-out | H | Acc % |
|---|---:|---:|
| AVGC | 0.7189 | 68.50 |
| DTU | 0.8436 | 74.71 |
| KUL | 0.8111 | 74.81 |
| UHD | 0.7898 | 73.19 |
| USTC | 0.8224 | 72.78 |
| **mean** | **0.7972** | **72.80** |

### a-grid (+ optional tip)

| Rule | mean H | mean Acc |
|---|---:|---:|
| `a=0` | 0.7488 | 66.82 |
| `a=0.25` | 0.7764 | 69.89 |
| `a=0.5` | 0.7914 | 72.09 |
| `a=0.75` **←** | 0.7972 | 72.80 |
| `a=1` | 0.7932 | 72.69 |
| `a=0+hard_abs_swmix|t1|s1` | 0.7578 | 67.59 |
| `a=0.25+hard_abs_swmix|t1|s1` | 0.7789 | 70.37 |
| `a=0.5+hard_abs_swmix|t1|s1` | 0.7916 | 72.19 |
| `a=0.75+hard_abs_swmix|t1|s1` | 0.7942 | 72.68 |
| `a=1+hard_abs_swmix|t1|s1` | 0.7928 | 72.61 |

## External (preset)

| Set | selected H/Acc | tip Acc leader | SW2 a=0.5 | linear_hp30 |
|---|---|---|---|---|
| AASD | 0.6427 / **53.12** | 0.6424/53.53 | 0.6439/53.46 | 0.6422/53.12 |
| Carta2026 | 0.6467 / **59.50** | 0.6460/59.71 | 0.6470/59.60 | 0.6520/60.54 |

## Targets

| Target | Result |
|---|---|
| AASD Acc vs tip 53.53 / hp30 53.12 | Acc **53.12** (Δtip -0.41; Δhp +0.00); H 0.6427 |
| Carta vs hp30 60.54 | Acc **59.50** (Δ -1.04); H 0.6467 |
| LODO mean | H 0.7972 Acc 72.80 |
| AASD Acc>60? | NO |

## Verdict

Honest LODO Acc/H selector over fuse_general a (and a+tip hard_abs) does not create AASD Acc>60. Mix weight a alone stays in the Acc mid-50s portfolio.

## NEXT IDEA

Do not re-grid fuse_general a on published SW2 under LODO Acc/H — Acc stays mid-50s. Prefer a qualitatively new Acc front-end (clf denser switch FT already in flight) or Carta-side path that preserves hp30 Acc 60.54 without collapsing AASD. Keep tip Acc 53.53 and linear_hp30 Carta 60.54 as portfolio leaders.